Description
High ventilation performance
• Sophisticated ventilation modes for critically ill patients (e.g. PC-APRV, VC-MMV, AutoFlow®)
• Enhanced trigger detection and precise ventilation settings allow the ventilation of babies starting from 5 kg bodyweight
• Automatic Tube Compensation ATC® reduces the work of breathing for intubated patients with spontaneous breathing
• Stress-free spontaneous breathing with excellent trigger response time thanks to the turbine
• Free breathing with AutoFlow in volume constant ventilation at a minimum pressure level
• Non-invasive ventilation (NIV) available in all modes with a very quick response times to patient efforts
• No device change needed in case of altered ventilation therapy: O2-therapy allows oxygen application with constant flow
• Extended graphic capabilities with loops, trends and logbook
Independent from gas and power supply
• Built-in-turbine with rapid response time and continuous high flow delivery of up to 250 L/min
• Five hours of independent ventilation due to built-in and external batteries
• Transport Supply Unit (TSU) can be quickly attached for ergonomic handling of gas cylinders
• Bed coupling for quick connection between ventilator and patient bed
• Low Pressure Oxygen (LPO) inlet for ventilation without central gas supply
Basic configuration:
• for ventilating adults and pediatric patients with a tidal volume of at least 50 mL (option 20 mL)
• for simultaneous display of 3 realtime waveforms
• configurable 12″ touchscreen
• for intensive care wards and recovery rooms
• new ergonomic design
Ventilation modes:
• VC-CMV/VC-AC: Volume Control – Continous Mandatory Ventilation / Volume Control-Assist Control
• VC-SIMV: Volume Control – Synchronized Intermittend Mandatory Ventilation
• SPN-CPAP: Spontaneous – Continuous Positive Airway Pressure
• PC-BIPAP: Pressure Control – Biphasic Positive Airway Pressure
• AutoFlow: Automatic adaption of the inspiratory flow in volume controlled ventilation modes
• NIV: Non Invasive Ventilation with automatic leakage compensation
• Quick Startup: guided therapy start with preset ventilation parameters based on patient height or patient category
• Monitoring Plus: displays loops, graphical and tabular trends
Displayed measured values:
• FiO2, PEEP, peak pressure, plateau pressure, mean airway pressure
• total and spontaneous minute volume (BTPS)
• total and spontaneous respiratory rate
• compliance and resistance
• expiratory tidal volume and leakage-compensated patient tidal volume (BTPS)
• realtime waveforms for flow, pressure, and volume
• ratio of inspiratory time to expiratory time (I:E)
• tabular display of measured values
• intuitive alarms
• logbook for recording alarms, changed settings, calibrations, and user actions
• dialog-based check of operational readiness (device check and breathing circuit check)
• oxygenation program for endotracheal suctioning
• manually triggered inspiration and inspiration hold
• port for pneumatic nebulizer
• leakage compensation
• integrated breathing-gas compressor (high-performance turbine)
• internal battery for an operating time of approx. 45 minutes
• delivered with 5 flow sensors und spare expiratory valve
Options
• Option LPO
• Option CO2
• Option PC-AC
• Option Special maneuvers
• Option O2 therapy
• Option PC-APRV
• Option ATC
• Option PediatricPlus
• Option: Nurse Call
• Option: VC-MMV
• Set external batteries (The external battery guarantees up to four additional hours of independent ventilation performance during patient transport).




Reviews
There are no reviews yet.