Fabius® MRI

Increase the diagnostic capability of your MRI unit with the help of stateof-the-art ventilation in the Dräger Fabius® MRI anaesthesia system specially designed for use in MRI environments. Specifically designed for use in magnetic environments, the Dräger Fabius MRI is certified for field strengths of up to 40 mTesla or 400 Gauss. This provides reliable ventilation with 1.5 and even 3 Tesla MRI systems.

Description

Increase the diagnostic capability of your MRI unit with the help of stateof-the-art ventilation in the Dräger Fabius® MRI anaesthesia system specially designed for use in MRI environments. Specifically designed for use in magnetic environments, the Dräger Fabius MRI is certified for field strengths of up to 40 mTesla or 400 Gauss. This provides reliable ventilation with 1.5 and even 3 Tesla MRI systems. The Dräger Fabius MRI incorporates a servo-controlled, piston ventilator that requires no drive gas. The piston is capable of delivering higher inspiratory flows than the traditional bellows ventilator, and provides a more accurate volume delivery. Electronically controlled and driven, high-precision ventilator optimizes performance of available ventilation modes: Volume-controlled; Pressure-controlled; Pressure support; and SIMV/PS. Compliance Compensation supports various lengths of breathing tube, plus “get what you set” tidal volume makes system practical for all patients, from neonates to adults.
The Fabius MRI has a compact breathing system, COSY 2.6 which can be mounted on the left or right hand side of the unit, depending on the room layout. Mounted on a short, 8” arm to provide positioning flexibility, it simplifies use in an often cramped MRI environment. The Fabius MRI also gives you the option of using the Dräger CLIC disposable soda lime absorber canister for an easy dust-free soda lime canister exchange.
Because it uses Dräger’s uniform user interface, Fabius MRI is quick and easy to learn. All relevant information is displayed on a single, high resolution LCD color screen (6.5 inch diagonal).
Anesthesia machine Fabius MRI
•suitable for adults, pediatric, and neonatal patients
•suitable for low-flow anesthesia

Main unit
-approved for operation in MRI scanner rooms with magnets 1.5 tesla and 3 tesla at a fringe field strength of up to 40 mtesla (400 gauss)
-two additional large optical alarm indicators (LED)
-two independent Tesla sensors with acoustic alarm for 40 mtesla limit
-3-gas version O2/N2O/AIR
-mechanically controlled fresh-gas delivery with electronic measurement and display
-double vapor mount
-sensitive oxygen ratio controller
-additional O2 flow tube for independent O2 dosage
-connections for certified gas cylinders usable for MRI
-battery backup for monitoring and ventilation for up to 120 minutes
-two integrated, country-specific power outlets
-pull-out writing tray
-three storage drawers
-4-wheel central brake

Piston ventilator
-integrated, electronically controlled and electrically driven ventilator requiring no driving gas
-Manual/Spontaneous, Volume Control, Pressure Control, and Pressure Support ventilation modes
-SIMV/PS mode for synchronized, volume-controlled ventilation with optional pressure support
-compliance compensation in volume-controlled ventilation modes
-fresh-gas decoupled

Compact Breathing System (COSY)
-integrated flow measurement
-swivel arm for mounting on left or right side of device